Production · daylight · larger roofs

Continuous rooflights
for bright, practical interiors.

Segmental and barrel-vault solutions for natural lighting of production, storage and business premises. We coordinate the dimensions, filling, upstands and ventilation or smoke exhaust with your facility.

Continuous rooflights on an industrial roof.
Continuous rooflights on an industrial roof.
Segmental or archedtwo continuous rooflight designs
1–6 m openingscatalogue range of arched strip widths
Lighting + openingaccording to the purpose and requirements of the facility

From space to solution

Which rooflight system suits your roof?

Segmental continuous rooflights

Segmental continuous rooflights arranged across the roof.
Segmental continuous rooflights arranged across the roof.

Modular single-layer or double-layer elements made of acrylic or polycarbonate glazing. The length is assembled with middle and adjusted end elements.

Composition and standard dimensions →

Barrel-vault rooflights

Barrel-vault rooflight with opening parts.
Barrel-vault rooflight with opening parts.

Aluminium construction with thermally separated profiles and cellular polycarbonate infill. Solution for wider openings and larger closed light surfaces.

Construction and comparison of infills →

When choosing, we take into account flat or gable roof, structural opening, space heating, desired light transmission, loads and the need for opening. Ventilation and NSHEV are planned specifically.

PMMA or polycarbonate glazing

Segmented rooflights: a flexible modular system.

Single-layer or double-layer elements made of acrylic (PMMA) or polycarbonate glazing are installed directly on the extension upstands. Intermediate elements and adapted end parts allow the assembly of the total length. Opening mechanisms can also be added later, after checking the existing design and compatibility.

Cross-section and longitudinal drawing of a segmental rooflight.
Cross-section and longitudinal drawing of a segmental rooflight.

Dimensional markings

L – clear dimension
K – construction dimension
S – screw axis
Z – external dimension
H – upstand height
SE – middle element
PKE – adapted end element

Please indicate the measuring points and unit on request. The total length and arrangement of the opening parts are confirmed before production.

Standard dimensions of segment strips in centimetres
Segment continuous rooflights; dimensions are in centimetres
L (cm) K (cm) S (cm) Z (cm) PKE min. (cm) PKE max. (cm) SE (cm)
80 100 86 100 50 180 180
100 120 106 120 50 180 180
125 145 131 145 50 180 180
150 170 156 170 50 180 180
175 195 181 195 50 180 180
200 220 206 220 50 180 180
215 235 221 235 50 180 180
225 245 231 245 50 180 180

On a smaller screen, scroll the table left or right for all data.

Ask about segmental rooflights

Aluminium structure and cellular PC

Barrel-vault rooflights: wider spans and glazing options.

The supporting structure consists of extruded aluminium profiles. Separate inner supporting and outer covering profiles provide thermal separation along the arch. The UV-resistant cellular polycarbonate filling is selected according to thermal, light and project requirements.

Basic dimensions and construction of the arch strip
Parameter Catalog version
Roof opening width 1,000–6,000 mm
Length Modular; total length and division are confirmed for the project
Rooflight upstand Galvanized metal, straight or inclined
Upstand height 30–70 cm
Insulation preparation Up to 10 cm
Surface Standard untreated aluminium profiles; upstand also RAL by arrangement

On a smaller screen, scroll the table left or right for all data.

Compare five polycarbonate filling compositions
Polycarbonate fillings for barrel-vault rooflights
Infill Ug Reaction to fire Rw
PC 10-5 2.5 W/m²K B-s1,d0 17 dB
PC 16-7 1.8 W/m²K B-s1,d0 20 dB
PC 10-5 + PC 10-5 1.25 W/m²K B-s1,d0 18 dB
PC 16-7 + PC 10-5 1.04 W/m²K B-s1,d0 20 dB
PC 16-7 + PC 16-7 0.95 W/m²K B-s1,d0 20 dB

On a smaller screen, scroll the table left or right for all data.

Ug, Rw and the reaction to fire are the data of the specified filling. The properties of the entire installed strip also depend on the frames, upstand, joints and design.

For the described arch systems, the catalogue lists the classification BROOF(t1) and fall resistance tests. The validity of the documentation is checked for the specific composition and dimensions. The continuous rooflight is not intended as a walking surface.

Ask about barrel-vault rooflights

Dedicated opening solution

Daylight, ventilation and twin-flap vents.

Ventilator with double open flap.
Ventilator with double open flap.

Daylight ventilation or fire function

The double flap combines the supply of daylight with dedicated opening. We adapt the different shapes of flaps, flanges and bases to the installation. The housing is made of corrosion-resistant aluminium.

For daily ventilation, a double pneumatic cylinder P2 or an electric drive 230 V. Smoke ventilation uses P2F with thermal triggering or a dedicated 24-V drive is provided.

Dimensions of the double flap ventilator
Parameter Double flap
Opening width 1,000–2,500 mm
Opening length 1,000–3,500 mm
Opening angle Up to 90°
Accessories Bird or insect net, fall protection, RAL versions - according to configuration

On a smaller screen, scroll the table left or right for all data.

Double flap fillings from the catalogue
Fillings and opaque compositions for double flaps
Infill Ug Rw
PC 16-9 / PC 16-9 TG 1.77 W/(m²K) 20 dB
PC 25-7X / PC 25-7X TG 1.4 W/(m²K) 24 dB
PC 32-11 / PC 32-11 TG 1.1 W/(m²K) 21 dB
Alu-sandwich panel, version 1 1.77 W/(m²K) 39 dB
Alu-sandwich panel, version 2 0.85 W/(m²K) 39 dB

On a smaller screen, scroll the table left or right for all data.

Single-chamber and double-chamber aluminium profiles (TG) are available. The alu-sandwich panel is opaque and does not transmit daylight. The final composition and documentation are coordinated according to the project requirements. These values ​​​​are not data for the entire installed device.

NSHEV is part of the fire design of the building. Normal daily ventilation is not a substitute for it; the required areas, control, power supply and evidence are determined for the selected device.

Check the data for the NSHEV system design →

Coordinate the opening

Details for a complete installation

Complete the system with upstands and accessories.

Connection to the roof

The upstand and height are selected according to the final roof composition. During renovation, we check corrosion, fastening, insulation and waterproofing finish. The detail of the roof connection is part of the installation solution.

More about rooflight upstands →

Opening control

Individual or group control, power supply, sensors and activation are determined depending on the purpose. For daily ventilation, we can provide a rain and wind sensor.

Nets and maintenance

Protective nets and bird or insect nets must be compatible with opening. The equipment must not disable the intended function of the element. Inspections and service are adapted to the installed system.

Designs and details

Examples of continuous rooflights.

Segmented strip with an open part for ventilation.
Segmented strip with an open part for ventilation.
Continuous rooflights on a roof with sheet metal roofing.
Continuous rooflights on a roof with sheet metal roofing.
Opening part and protective mesh in an arched continuous rooflight.
Opening part and protective mesh in an arched continuous rooflight.
Detail of the continuous rooflight's mounting and opening equipment.
Detail of the continuous rooflight's mounting and opening equipment.

The photos show different versions from the program. The selected facility requires its own coordination of dimensions, filling and equipment.

Renovation carried out · Šenčur

Renovation of Cargo-partner continuous rooflights.

At the facility in Šenčur, the renovation covered 39 continuous rooflights, including strips up to 60 m long. 1,300 m² of 16 mm opal Lexan polycarbonate sheets were installed. The solution also includes natural ventilation.

The example shows that when renovating a large roof area, we consider the infill, existing structure and opening together.

Read the full reference on kupole.net ↗

Are you planning a similar renovation?

Send the number and approximate dimensions of the strips, photos of the existing condition, type of roofing and a description of the problem. Indicate whether you want to maintain or improve ventilation.

Ask about renovation →

Supply · installation · maintenance

New installations and rooflight refurbishment.

We supply, install, and perform agreed inspections, maintenance, and renovation of rooflights. When replacing the infill, we also check the profiles, upstands, fasteners, and opening parts. Replacing the infill itself does not correct the error in another part of the roof system.

  1. Building details: location, purpose of the hall, new construction or renovation.
  2. Basic dimensions: number of strips, width and total length of openings, sketch and cross-section of the roof.
  3. Desired function: daylight, ventilation or NSHEV.
  4. Specification and quotation: confirmation of the infill, equipment, access, delivery, and scope of work.

If you do not have all the information yet, start with photos and approximate dimensions. Measurements that require working at height should be carried out by a qualified contractor. We confirm the final dimensions before construction.

For your facility

What kind of continuous rooflight do you need?

Select the design and purpose; we will transfer the selection to the form. There, fill in the dimensions, quantity, location of the facility and a description of the need.

You can send a sketch or photos to [email protected]. We prepare an offer for project-specific solutions; continuous rooflights are not standard items for direct online purchase.

Before choosing

Frequently asked questions about continuous rooflights.

Can the strip be installed on a gable roof?

Yes, the program includes solutions for flat and gable roofs. The slope, construction, opening and connection details are confirmed for the building.

Is the length of the continuous rooflight unlimited?

The modular design allows for the assembly of longer strips. The total length, division, load capacity, opening and installation must be confirmed for the specific project.

Can the opening be added later?

For segment systems, a subsequent upgrade is possible after checking compatibility. For NSHEV, the complete unit and its configuration must be verified for smoke ventilation.

Can I walk on the continuous rooflight?

The continuous rooflight is not a walking surface. The fall resistance test does not mean that you can walk on it.

What has the greatest impact on the price?

System type, width, total length, filling, upstand, opening parts, control and scope of installation or renovation. Transport, access, dismantling and roof finishes are coordinated in the offer.

Which documentation do I receive?

The documentation is selected based on the actual dimensions, filling, drive and purpose. When inquiring, please state the required plans, performance statements and any fire requirements.

Data according to the POS Plastika product range and the Rooflight domes and strips catalogue, edition 2026. The final dimensions, composition, equipment and associated documentation are confirmed in the offer.

Analytics cookies
These cookies help us understand how visitors use the website so that we can improve its content and usability.
Social media cookies
These cookies support embedded social media content and sharing features.
Communication cookies
These cookies support communication features such as chat tools on the website.
Marketing cookies
These cookies help show relevant advertisements based on browsing activity.
What are cookies?
By visiting and using the site, you consent to the use and recording of cookies.OK Learn more about cookies